summaryrefslogtreecommitdiff
path: root/INSTALL
diff options
context:
space:
mode:
authorKlaus Schmidinger <kls (at) cadsoft (dot) de>2006-08-06 18:00:00 +0200
committerKlaus Schmidinger <kls (at) cadsoft (dot) de>2006-08-06 18:00:00 +0200
commit33f1491b18c201ecda4ff2c34f606d9f5f041489 (patch)
tree32f49da0229fb93b1e0ceb92aa099d16f1562751 /INSTALL
parent80c04529681b844de88cfa47ec743f847b37d7a2 (diff)
downloadvdr-patch-lnbsharing-33f1491b18c201ecda4ff2c34f606d9f5f041489.tar.gz
vdr-patch-lnbsharing-33f1491b18c201ecda4ff2c34f606d9f5f041489.tar.bz2
Version 1.4.1-3vdr-1.4.1-3
- Fixed assigning schedules to channels in case there is no initial EPG information (thanks to Frank Schmirler). - Increased the APIVERSION to allow plugins that relied on the cStatus::MsgSetVolume() bug to react properly (suggested by Stefan Huelswitt). - Fixed cDevice::ToggleMute() (thanks to Christoph Haubrich). - Fixed deleting the last character of a string menu item in insert mode (thanks to Udo Richter). - The /video/.update file is now touched _after_ an editing process is finished in order to avoid excessive disk access (thanks to Artur Skawina). - Fixed handling the running status of EPG events before the currently running one, in case they are added after the current event (cont'd from version 1.4.1-2). - Modified the shutdown mechanism, so that the shutdown script is never given a time in the past (reported by Helmut Auer). If a timer is currently recording, or a recording would start within the next 30 minutes (default for the "Min. event timeout" setup parameter), and the user insists in shutting down now, the reboot time given to the shutdown script will correspond to a time that is "Min. event timeout" minutes (default is 30) in the future. - Avoiding shutdown message "Recording in ... minutes, shut down anyway?" with a negative number of minutes (reported by Udo Richter). - Fixed getting the next active timer when shutting down (thanks to Udo Richter). - Modified the cSVDRP::Close() function to avoid code duplication.
Diffstat (limited to 'INSTALL')
-rw-r--r--INSTALL11
1 files changed, 5 insertions, 6 deletions
diff --git a/INSTALL b/INSTALL
index 6cbc8b5..fef8601 100644
--- a/INSTALL
+++ b/INSTALL
@@ -171,7 +171,7 @@ calling the shutdown program, but will rather continue normally until it
receives a SIGTERM when the computer is actually shut down. So in case
the shutdown fails, or the shutdown program for some reason decides not to
perform a shutdown, VDR will stay up and running and will call the shutdown
-program again after another MinUserInactivity minutes.
+program again after another five minutes.
If there are currently no timers active, both parameters will be '0'.
In that case the program shall not set the hardware for automatic restart
@@ -191,11 +191,10 @@ that this is a user requested shutdown (resulting from pressing the "Power"
key). The shutdown program may use this information to decide whether or
not to actually perform the system shutdown.
-If a timer is currently recording, the parameters will reflect the start
-time of that timer. This means that the first parameter will be a time in
-the past, and the second parameter will be a negative number. This only
-happens if the user presses the "Power" key while a timer is currently
-recording.
+If a timer is currently recording, or a recording would start within the
+next 30 minutes (default for the "Min. event timeout" setup parameter), and
+the user insists in shutting down now, the first and second parameter will
+correspond to a time that is "Min. event timeout" minutes in the future.
Before the shutdown program is called, the user will be prompted to inform
him that the system is about to shut down. If any remote control key is